Now showing1 - 7 of 7
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: with files ,
    A review of deep learning-based unsupervised anomaly detection in brain MRI
    The manual assessment of brain Magnetic Resonance Imaging (MRI) scans can be labor-intensive and time-consuming for radiologists. Deep Learning methods have demonstrated the potential to aid this process. However, their effectiveness relies on the availability of large, annotated data sets. Unsupervised Anomaly Detection (UAD) presents a promising alternative, offering the potential to identify and localize anomalies without per-pixel annotations. Instead, a normative distribution is learned using healthy data, enabling the identification of abnormalities as deviations. This allows UAD methods to detect abnormalities that were unseen during training. This appealing feature has led to numerous studies proposing innovations and novel approaches. In this work, we provide a review of the literature and systematically collect and compare the proposed approaches. We observe that UAD has made significant advancements in brain MRI analysis. However, individual approaches are often evaluated in different contexts, i.e., changes in acquisition parameters, pre- and post-processing, and anomaly scoring. This variability makes it challenging to assess which models perform best, underscoring the need for comprehensive comparative studies concerning the specific context of MRI scans. Our collection, featuring public data sets, research studies, and open implementations, is available at our GitHub repository https://github.com/FinnBehrendt/Unsupervised-Anomaly-Detection-in-Brain-MRI .
    Publicationtype: Review Article
      14  26
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: with files ,
    Validating polyp and instrument segmentation methods in colonoscopy through Medico 2020 and MedAI 2021 Challenges
    (Elsevier, 2025-01) ; ; ; ;
    Roy, Kaushiki
    Automatic analysis of colonoscopy images has been an active field of research motivated by the importance of early detection of precancerous polyps. However, detecting polyps during the live examination can be challenging due to various factors such as variation of skills and experience among the endoscopists, lack of attentiveness, and fatigue leading to a high polyp miss-rate. Therefore, there is a need for an automated system that can flag missed polyps during the examination and improve patient care. Deep learning has emerged as a promising solution to this challenge as it can assist endoscopists in detecting and classifying overlooked polyps and abnormalities in real time, improving the accuracy of diagnosis and enhancing treatment. In addition to the algorithm's accuracy, transparency and interpretability are crucial to explaining the whys and hows of the algorithm's prediction. Further, conclusions based on incorrect decisions may be fatal, especially in medicine. Despite these pitfalls, most algorithms are developed in private data, closed source, or proprietary software, and methods lack reproducibility. Therefore, to promote the development of efficient and transparent methods, we have organized the “Medico automatic polyp segmentation (Medico 2020)” and “MedAI: Transparency in Medical Image Segmentation (MedAI 2021)” competitions. The Medico 2020 challenge received submissions from 17 teams, while the MedAI 2021 challenge also gathered submissions from another 17 distinct teams in the following year. We present a comprehensive summary and analyze each contribution, highlight the strength of the best-performing methods, and discuss the possibility of clinical translations of such methods into the clinic. Our analysis revealed that the participants improved dice coefficient metrics from 0.8607 in 2020 to 0.8993 in 2021 despite adding diverse and challenging frames (containing irregular, smaller, sessile, or flat polyps), which are frequently missed during a routine clinical examination. For the instrument segmentation task, the best team obtained a mean Intersection over union metric of 0.9364. For the transparency task, a multi-disciplinary team, including expert gastroenterologists, accessed each submission and evaluated the team based on open-source practices, failure case analysis, ablation studies, usability and understandability of evaluations to gain a deeper understanding of the models’ credibility for clinical deployment. The best team obtained a final transparency score of 21 out of 25. Through the comprehensive analysis of the challenge, we not only highlight the advancements in polyp and surgical instrument segmentation but also encourage subjective evaluation for building more transparent and understandable AI-based colonoscopy systems. Moreover, we discuss the need for multi-center and out-of-distribution testing to address the current limitations of the methods to reduce the cancer burden and improve patient care.
    Publicationtype: Journal Article
      20  22
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Posterior temperature optimized Bayesian models for inverse problems in medical imaging
    We present Posterior Temperature Optimized Bayesian Inverse Models (POTOBIM), an unsupervised Bayesian approach to inverse problems in medical imaging using mean-field variational inference with a fully tempered posterior. Bayesian methods exhibit useful properties for approaching inverse tasks, such as tomographic reconstruction or image denoising. A suitable prior distribution introduces regularization, which is needed to solve the ill-posed problem and reduces overfitting the data. In practice, however, this often results in a suboptimal posterior temperature, and the full potential of the Bayesian approach is not being exploited. In POTOBIM, we optimize both the parameters of the prior distribution and the posterior temperature with respect to reconstruction accuracy using Bayesian optimization with Gaussian process regression. Our method is extensively evaluated on four different inverse tasks on a variety of modalities with images from public data sets and we demonstrate that an optimized posterior temperature outperforms both non-Bayesian and Bayesian approaches without temperature optimization. The use of an optimized prior distribution and posterior temperature leads to improved accuracy and uncertainty estimation and we show that it is sufficient to find these hyperparameters per task domain. Well-tempered posteriors yield calibrated uncertainty, which increases the reliability in the predictions. Our source code is publicly available at github.com/Cardio-AI/mfvi-dip-mia.
    Publicationtype: Journal Article
    Scopus© Citations 4  28
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Deep learning with 4D spatio-temporal data representations for OCT-based force estimation
    Estimating the forces acting between instruments and tissue is a challenging problem for robot-assisted minimally-invasive surgery. Recently, numerous vision-based methods have been proposed to replace electro-mechanical approaches. Moreover, optical coherence tomography (OCT) and deep learning have been used for estimating forces based on deformation observed in volumetric image data. The method demonstrated the advantage of deep learning with 3D volumetric data over 2D depth images for force estimation. In this work, we extend the problem of deep learning-based force estimation to 4D spatio-temporal data with streams of 3D OCT volumes. For this purpose, we design and evaluate several methods extending spatio-temporal deep learning to 4D which is largely unexplored so far. Furthermore, we provide an in-depth analysis of multi-dimensional image data representations for force estimation, comparing our 4D approach to previous, lower-dimensional methods. Also, we analyze the effect of temporal information and we study the prediction of short-term future force values, which could facilitate safety features. For our 4D force estimation architectures, we find that efficient decoupling of spatial and temporal processing is advantageous. We show that using 4D spatio-temporal data outperforms all previously used data representations with a mean absolute error of 10.7 mN. We find that temporal information is valuable for force estimation and we demonstrate the feasibility of force prediction.
    Publicationtype: Journal Article
      94
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Learning metal artifact reduction in cardiac CT images with moving pacemakers
    Metal objects in the human heart such as implanted pacemakers frequently lead to heavy artifacts in reconstructed CT image volumes. Due to cardiac motion, common metal artifact reduction methods which assume a static object during CT acquisition are not applicable. We propose a fully automatic Dynamic Pacemaker Artifact Reduction (DyPAR+) pipeline which is built of three convolutional neural network (CNN) ensembles. In a first step, pacemaker metal shadows are segmented directly in the raw projection data by the SegmentationNets. Second, resulting metal shadow masks are passed to the InpaintingNets which replace metal-affected line integrals in the sinogram for subsequent reconstruction of a metal-free image volume. Third, the metal locations in a pre-selected motion state are predicted by the ReinsertionNets based on a stack of partial angle back-projections generated from the segmented metal shadow mask. We generate the data required for the supervised learning processes by introducing synthetic, moving pacemaker leads into 14 clinical cases without pacemakers. The SegmentationNets and the ReinsertionNets achieve average Dice coefficients of 94.16% ± 2.01% and 55.60% ± 4.79% during testing on clinical data with synthetic metal leads. With a mean absolute reconstruction error of 11.54 HU ± 2.49 HU in the image domain, the InpaintingNets outperform the hand-crafted approaches PatchMatch and inverse distance weighting. Application of the proposed DyPAR+ pipeline to nine clinical test cases with real pacemakers leads to significant reduction of metal artifacts and demonstrates the transferability to clinical practice. Especially the SegmentationNets and InpaintingNets generalize well to unseen acquisition modes and contrast protocols.
    Publicationtype: Journal Article
      118
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Motion artifact recognition and quantification in coronary CT angiography using convolutional neural networks
    Excellent image quality is a primary prerequisite for diagnostic non-invasive coronary CT angiography. Artifacts due to cardiac motion may interfere with detection and diagnosis of coronary artery disease and render subsequent treatment decisions more difficult. We propose deep-learning-based measures for coronary motion artifact recognition and quantification in order to assess the diagnostic reliability and image quality of coronary CT angiography images. More specifically, the application, steering and evaluation of motion compensation algorithms can be triggered by these measures. A Coronary Motion Forward Artifact model for CT data (CoMoFACT) is developed and applied to clinical cases with excellent image quality to introduce motion artifacts using simulated motion vector fields. The data required for supervised learning is generated by the CoMoFACT from 17 prospectively ECG-triggered clinical cases with controlled motion levels on a scale of 0-10. Convolutional neural networks achieve an accuracy of 93.3% ± 1.8% for the classification task of separating motion-free from motion-perturbed coronary cross-sectional image patches. The target motion level is predicted by a corresponding regression network with a mean absolute error of 1.12 ± 0.07. Transferability and generalization capabilities are demonstrated by motion artifact measurements on eight additional CCTA cases with real motion artifacts.
    Publicationtype: Journal Article
      310
  • Some of the metrics are blocked by your 
    Item type:Publication,
    A deep learning approach for pose estimation from volumetric OCT data
    Tracking the pose of instruments is a central problem in image-guided surgery. For microscopic scenarios, optical coherence tomography (OCT) is increasingly used as an imaging modality. OCT is suitable for accurate pose estimation due to its micrometer range resolution and volumetric field of view. However, OCT image processing is challenging due to speckle noise and reflection artifacts in addition to the images’ 3D nature. We address pose estimation from OCT volume data with a new deep learning-based tracking framework. For this purpose, we design a new 3D convolutional neural network (CNN) architecture to directly predict the 6D pose of a small marker geometry from OCT volumes. We use a hexapod robot to automatically acquire labeled data points which we use to train 3D CNN architectures for multi-output regression. We use this setup to provide an in-depth analysis on deep learning-based pose estimation from volumes. Specifically, we demonstrate that exploiting volume information for pose estimation yields higher accuracy than relying on 2D representations with depth information. Supporting this observation, we provide quantitative and qualitative results that 3D CNNs effectively exploit the depth structure of marker objects. Regarding the deep learning aspect, we present efficient design principles for 3D CNNs, making use of insights from the 2D deep learning community. In particular, we present Inception3D as a new architecture which performs best for our application. We show that our deep learning approach reaches errors at our ground-truth label's resolution. We achieve a mean average error of 14.89 ± 9.3 µm and 0.096 ± 0.072° for position and orientation learning, respectively.
    Publicationtype: Journal Article
      265