Item type:Publication, Access status: without files , The influence of age on adaptive bone formation and bone resorption(Elsevier, 2014-11) ;Birkhold, Annette I. ;Razi, Hajar; ; Bone is a tissue with enormous adaptive capacity, balancing resorption and formation processes. It is known that mechanical loading shifts this balance towards an increased formation, leading to enhanced bone mass and mechanical performance. What is not known is how this adaptive response to mechanical loading changes with age. Using dynamic micro-tomography, we show that structural adaptive changes of trabecular bone within the tibia of living mice subjected to two weeks of invivo cyclic loading are altered by aging. Comparisons of 10, 26 and 78 weeks old animals reveal that the adaptive capacity diminishes. Strikingly, adaptation was asymmetric in that loading increases formation more than it reduces resorption. This asymmetry further shifts the (re)modeling balance towards a net bone loss with age. Loading results in a major increase in the surface area of mineralizing bone. Interestingly, the resorption thickness is independent of loading in trabecular bone in all age groups. This data suggests that during youth, mechanical stimulation induces the recruitment of bone modeling cells whereas in old age, only bone forming cells are affected. These findings provide mechanistic insights into the processes that guide skeletal aging in mice as well as in other mammals.Publicationtype: Journal Article11 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , A mechanical microconnector system for restoration of tissue continuity and long-term drug application into the injured spinal cord(Elsevier, 2013-10-03); ; ; ; Complete transection of the spinal cord leaves a gap of several mm which fills with fibrous scar tissue. Several approaches in rodent models have used tubes, foams, matrices or tissue implants to bridge this gap. Here, we describe a mechanical microconnector system (mMS) to re-adjust the retracted spinal cord stumps. The mMS is a multi-channel system of polymethylmethacrylate (PMMA), designed to fit into the spinal cord tissue gap after transection, with an outlet tubing system to apply negative pressure to the mMS thus sucking the spinal cord stumps into the honeycomb-structured holes. The stumps adhere to the microstructure of the mMS walls and remain in the mMS after removal of the vacuum. We show that the mMS preserves tissue integrity and allows axonal regrowth at 2, 5 and 19 weeks post lesion with no adverse tissue effects like in-bleeding or cyst formation. Preliminary assessment of locomotor function in the open field suggested beneficial effects of the mMS. Additional inner micro-channels enable local substance delivery into the lesion center via an attached osmotic minipump. We suggest that the mMS is a suitable device to adapt and stabilize the injured spinal cord after surgical resection of scar tissue (e.g., for chronic patients) or traumatic injuries with large tissue and bone damages.Publicationtype: Journal Article89 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Crack arrest within teeth at the dentinoenamel junction caused by elastic modulus mismatch(Elsevier, 2010-05); ; ; ; Enamel and dentin compose the crowns of human teeth. They are joined at the dentinoenamel junction (DEJ) which is a very strong and well-bonded interface unlikely to fail within healthy teeth despite the formation of multiple cracks within enamel during a lifetime of exposure to masticatory forces. These cracks commonly are arrested when reaching the DEJ. The phenomenon of crack arrest at the DEJ is described in many publications but there is little consensus on the underlying cause and mechanism. Explanations range from the DEJ having a larger toughness than both enamel and dentin up to the assumption that not the DEJ itself causes crack arrest but the so-called mantle dentin, a thin material layer close to the DEJ that is somewhat softer than the bulk dentin. In this study we conducted 3-point bending experiments with bending bars consisting of the DEJ and surrounding enamel and dentin to investigate crack propagation and arrest within the DEJ region. Calculated stress intensities around crack tips were found to be highly influenced by the elastic modulus mismatch between enamel and dentin and hence, the phenomenon of crack arrest at the DEJ could be explained accordingly via this elastic modulus mismatch.Publicationtype: Journal ArticleScopus© Citations 71 750 981 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Simulation of angiogenesis and cell differentiation in a CaP scaffold subjected to compressive strains using a lattice modeling approach(Elsevier, 2010-03-01) ;Sandino, Clara; ;Prendergast, Patrick J.Mechanical stimuli are one of the factors that influence tissue differentiation. In the development of biomaterials for bone tissue engineering, mechanical stimuli and formation of a vascular network that transport oxygen to cells within the pores of the scaffolds are essential. Angiogenesis and cell differentiation have been simulated in scaffolds of regular porosity; however, the dynamics of differentiation can be different when the porosity is not uniform. The objective of this study was to investigate the effect of the mechanical stimuli and the capillary network formation on cell differentiation within a scaffold of irregular morphology. A porous scaffold of calcium phosphate based glass was used. The pores and the solid phase were discretized using micro computed tomography images. Cell activity was simulated within the interconnected pore domain of the scaffold using a lattice modeling approach. Compressive strains of 0.5 and 1% of total deformation were applied and two cases of mesenchymal stem cells initialization (in vitro seeding and in vivo) were simulated. Similar capillary networks were formed independently of the cell initialization mode and the magnitude of the mechanical strain applied. Most of vessels grew in the pores at the periphery of the scaffolds and were blocked by the walls of the scaffold. When 0.5% of strain was applied, 70% of the pore volume was affected by mechano-regulatory stimuli corresponding to bone formation; however, because of the lack of oxygen, only 40% of the volume was filled with osteoblasts. 40% of volume was filled with chondrocytes and 3% with fibroblasts. When the mechanical strain was increased to 1%, 11% of the pore volume was filled with osteoblasts, 59% with chondrocytes, and 8% with fibroblasts. This study has shown the dynamics of the correlation between mechanical load, angiogenesis and tissue differentiation within a scaffold with irregular morphology.Publicationtype: Journal Article8 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Size-dependent elastic-inelastic behavior of enamel over millimeter and nanometer length scales(Elsevier, 2010); ; ; ; The microstructure of enamel like most biological tissues has a hierarchical structure which determines their mechanical behavior. However, current studies of the mechanical behavior of enamel lack a systematic investigation of these hierarchical length scales. In this study, we performed macroscopic uni-axial compression tests and the spherical indentation with different indenter radii to probe enamel’s elastic/inelastic transition over four hierarchical length scales, namely: ‘bulk enamel’ (mm), ‘multiple-rod’ (10’s µm), intra-rod’ (100’s nm with multiple crystallites) and finally ‘single-crystallite’ (10’s nm with an area of approximately one hydroxyapatite crystallite). The enamel’s elastic/inelastic transitions were observed at 0.4-17GPa depending on the length scale and were compared with the values of synthetic hydroxyapatite crystallites. The elastic limit of a material is important as it provides insights into the deformability of the material before fracture. At the smallest investigated length scale (contact radius ~20nm), elastic limit is followed by plastic deformation. At the largest investigated length scale (contact size ~1mm), only elastic then micro-crack induced response was observed. A map of elastic/inelastic regions of enamel from millimeter to nanometer length scale is presented. Possible underlying mechanisms are also discussed.Publicationtype: Journal ArticleScopus© Citations 94 1205 849 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Proinflammatory and osteoclastogenic effects of beta-tricalciumphosphate and hydroxyapatite particles on human mononuclear cells in vitro(Elsevier, 2009-10-01); ; ; ;Haag, FriedrichParticulate wear debris can activate defence cells and osteoclasts at the bone-implant interface possibly leading to bone resorption and implant failure. Cellular responses and inflammatory effects have been reported for particulate hydroxyapatite (HA). However, the immunological effects of particulate beta-tricalciumphosphate (beta-TCP) have not been studied and the question of whether beta-TCP is more biocompatible in this regard as is HA remains to be determined. Therefore the present work investigates effects of endotoxin-free HA and beta-TCP particles of the same size (d50 = 1 μm) and dose (SAR 10:1) on human peripheral blood mononuclear cells in vitro. The production of proinflammatory cytokines (TNF-alpha, IL-1beta, IL-8) and cytokines connected to osteoclast and dendritic cell differentiation (OPG, RANKL, M-CSF, GM-CSF) was determined by ELISA. After 6 and 18 h of incubation HA and beta-TCP caused a quite similar induction of TNF-alpha, IL-1beta and IL-8. Effects of particles on the production of M-CSF and OPG were not detectable. However, in sharp contrast to HA, beta-TCP caused less induction of GM-CSF and not any of RANKL, both known for promoting dendritic cells and osteoclastogenesis respectively. Therefore these in vitro data suggest that wear debris of beta-TCP poses lesser risk of the detrimental effects of osteoclast induction known from HA.Publicationtype: Journal Article4 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , The fracture behaviour of dental enamel(Elsevier, 2009-01); ; ; ; Enamel is the hardest tissue in the human body covering the crowns of teeth. Whereas the underlying dental material dentin is very well characterised in terms of mechanical and fracture properties, available data for enamel are quite limited and are apart from the most recent investigation mainly based on indentation studies. Within the current study, stable crack-growth experiments in bovine enamel have been performed, to measure fracture resistance curves for enamel. Single edge notched bending specimens (SENB) prepared out of bovine incisors were tested in 3-point bending and subsequently analysed using optical and environmental scanning electron microscopy. Cracks propagated primarily within the protein-rich rod sheaths and crack propagation occurred under an inclined angle to initial notch direction not only due to enamel rod and hydroxyapatite crystallite orientation but potentially also due to protein shearing. Determined mode I fracture resistance curves ranged from 0,8 – 1,5 MPa*m1/2 at the beginning of crack propagation up to 4,4 MPa*m1/2 at 500 m crack extension; corresponding mode II values ranged from 0,3 to 1,5 MPa*m1/2.Publicationtype: Journal ArticleScopus© Citations 129 1870 1241